PL Get a quote

Resublimation heat pump

Heat
from water vapour.

Heating and hot water from the energy held in the air. All year round. Day and night. Even on frosty nights.

Scroll

The source

A source that
never runs out.

There is always water vapour in the air. Summer and winter, day and night. An inexhaustible source of energy.

Above 0 °C

It condenses
on the tubes.

Water vapour settles on the cold evaporator tubes as droplets. And gives off the heat of condensation.

Below 0 °C

It turns
into frost.

This is resublimation: vapour turns straight into frost and releases heat. Frost is no obstacle. The evaporator defrosts itself once the pump reaches the set temperature.

No fan

Silence
as standard.

No fan at all. Air flows around the tubes by itself.

No drilling

1,000 metres of pipe.
Zero digging.

That is how much horizontal ground loop the evaporator replaces. Or about 600 m of borehole. No excavator, no drilling rig, no dug-up garden.

R290 circuit

All the chemistry.
Outside.

The compressor and the natural refrigerant R290 stay outside the house. The boiler room needs no soundproofing and no emergency ventilation. Only the heat comes in.

Finish

Black
for a reason.

The black powder coating also lets the pump use the energy of sunlight.

Mobile

Moving house?
It moves with you.

The pump is not permanently tied to the building. When you move, you take it with you, and businesses can lease it.

The building

Heat where
you need it.

Through water pipes to underfloor heating and the hot water tank. The pump stands in the garden or on the roof.

In numbers

In numbers

4
seasonal SCOP, confirmed by users
2.0
COP even at −20 °C
2007
the year the first unit started running – non-stop ever since
15 years
warranty, at most
6
maximum COP

Heating cost

How many times more
other heat sources cost.2

Heating cost compared with the resublimation heat pump
Heating oil4.4×
Electric boiler, same tariff4.0×
Wood pellets2.7×
LPG2.6×
Natural gas1.9×
Coal (pea coal)1.8×
Resublimation heat pump1×

Savings calculator

Prices and assumptions

Average Polish market prices, November 2026. On the G12 tariff, a pump with a heat buffer runs about 70% of the time in the cheaper zone. Efficiency of current heat sources: gas 95%, oil 90%, LPG 92%, coal 75%, pellets 85%, electricity 99%.

Savings per year

–

Benefits

Benefits

No defrosting
No energy wasted on defrosting the evaporator, unlike conventional heat pumps.
Natural refrigerant R290
Propane instead of synthetic refrigerants, free of the restrictions on fluorinated greenhouse gases.
Maintenance-free
No fuel and no chimney. You control it online or by GSM, and our service team sees how it runs remotely.
Modular
Units combine into cascades of any output. While one is serviced, the others cover most of the demand.
Polish patent
About 20 patented solutions. Long-term warranty, up to 15 years.
With other sources and PV
The only heat source for supply temperatures up to 45 °C, or paired with an existing boiler. Even cheaper with solar panels.

Applications

From a home to a sports hall.

Homes

  • single-family houses
  • multi-family buildings

Businesses

  • shops and workshops
  • warehouses
  • petrol stations
  • industrial sites

Public buildings

  • schools
  • churches
  • sports halls
  • swimming pools

Visualisation

See it next to your home.

or drag it here · the photo stays in your browser

Models

Two models. Any output in a cascade.

SpecificationRES 8/48RES 16/81
Energy-efficient houseup to approx. 110 m²up to approx. 220 m²
Well-insulated houseup to approx. 70 m²up to approx. 150 m²
Output at +2 °C8.6 kW16.7 kW
Output at −20 °C5 kW10 kW
Dimensions (L × W × H)165 × 80 × 376 cm252 × 80 × 376 cm
Weight290 kg450 kg
Space needed outside3.0 × 2.0 m4.0 × 2.0 m

Versions Space heating · Domestic hot water · Both, with hot water priority  —  heating 45/35 °C, hot water 55 °C, process water up to 55 °C

Dimensions include the evaporator and the housing. The boiler room needs another approx. 2.2 × 1.4 m for the hydraulic module. Sizing is indicative: for underfloor heating (35 °C supply) and −20 °C outside. The pump runs up to 19 hours a day, so its output should exceed the building's heat load by about 26%. We assumed about 35 W/m² for an energy-efficient house and about 50 W/m² for a well-insulated one. We size each installation precisely after calculating the heat demand.

Contact

Let's talk about
your project.

Tell us the floor area and location of the building and the type of heating system. We will size the pump to its heat demand.

biuro@bsk-tech.pl +48 74 833 17 53

BSK TECH, ul. Jana III Sobieskiego 21, 58-260 Bielawa, Poland

How we handle the data from your enquiry is described in our privacy policy.